Clock Registers - Panasonic MN101L Series User Manual

Lsi
Table of Contents

Advertisement

12.2.5

Clock Registers

Seconds Setting Register (RTCSD: 0x03EE0)
bp
7
Bit name
-
At reset
0
Access
R
bp
Bit name
7
-
6 to 0
SD6 to 0
Minutes Setting Register (RTCMID: 0x03EE1)
bp
7
Bit name
-
At reset
0
Access
R
bp
Bit name
7
-
6 to 0
MID6 to 0
6
5
0
0
R/W
R/W
Always read as "0".
"Second" setting
Set a value within the range of "00" to "59" using the BCD format.
* The value which doesn't exist must not be set.
* The value is incremented by one from "00" to "59" per second.
6
5
0
0
R/W
R/W
Always read as 0.
"Minute" setting
Set a value within the range of "00" to "59" using the BCD format.
* The value which doesn't exist must not be set.
* The value is incremented by one from "00" to "59" per minute.
4
3
SD6-0
0
0
R/W
R/W
R/W
Description
4
3
MID6-0
0
0
R/W
R/W
R/W
Description
Real Time Clock (RTC)
2
1
0
0
R/W
R/W
2
1
0
0
R/W
R/W
Control Registers
Chapter 12
0
0
0
0
XII - 11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mn101lr05dMn101lr04dMn101lr03dMn101lr02d

Table of Contents