Timer 6 Enable Register

This register controls the starting operation of the timer 6 and the time base timer.
Timer 6 Enable Register (TM6BEN:0x03F7C)
bp
Bit name
At reset
Access
bp
7 to 2
1
0
X - 6
Control Registers
7
6
-
-
0
0
R
R
Bit name
-
Always read as 0.
Time base timer operation control
TBEN
0: Stop
1: Start
Timer 6 operation control
TM6EN
0: Stop
1: Start
5
4
-
-
0
0
R
R
Description
3
2
-
-
TBEN
0
0
R
R
R/W
1
0
TM6EN
0
0
R/W