Settings; Multi Test - DURKOPP ADLER D867 M-Type Delta Service Instructions Manual

Hide thumbs Also See for D867 M-Type Delta:
Table of Contents

Advertisement

4. Pull off the thread with the thread scale.
5. Change the percentage value (plus or minus) until the scale reads
6. Save the value and exit the menu.

19.8.2 Settings

The Settings parameter is not explained in greater detail here, because
it is closely related to the area of the mechanics. Details on that area can
be found in the Service routine chapter ( p. 14) .
Icon

19.8.3 Multi test

This parameter makes it possible to test whether, for example, magnets,
drives, and inputs or outputs are functioning correctly. A list of the neces-
sary allocations can be found in the  Parameter list of the machine.
Icon
178
200 cN.
Menu item
Feed dog
Hook-Needle
Sewing foot stroke
Menu items
Test Output
Test Input
Test Sewing Motor
Value range
Assemble
Position to needle
Feed dog movement
Timing
Needle bar
Equal sewing foot stroke
Feed Move
Value range
 p. 179
 p. 179
 p. 180
Service Instructions M-TYPE DELTA - 00.0 - 12/2019
Programming

Advertisement

Table of Contents
loading

Table of Contents