Setting The Sewing Speed Parameters - DURKOPP ADLER D867 M-Type Delta Service Instructions Manual

Hide thumbs Also See for D867 M-Type Delta:
Table of Contents

Advertisement

19.4.3 Setting the Sewing speed parameters

Various settings can be made for the sewing speed. The possibilities are
explained in more detail in the table.
Icon
130
Menu item
Max. Speed
Maximum permissible speed; it can no
longer be exceeded on the operator level.
Min. Speed
Minimum speed at which an individual
stitch is made; a lower speed is no longer
possible at operator level.
Position speed
The last stitch is made slower during stop-
ping of the sewing procedure.
Soft start speed
Reduced sewing speed for the first
stitches when sewing begins to sew on
the material securely
Number of soft start stitches
Acceleration
Slope of the acceleration ramp
Deceleration
Slope of the deceleration ramp
Speed limitation DB3000
Reduction of the speed to 3000 (rpm) in
combination with an activated input signal
Speed limitation DB2000
Reduction of the speed to 2000 (rpm) in
combination with an activated input signal
Service Instructions M-TYPE DELTA - 00.0 - 12/2019
Programming
Value range
• Value range
0500 - 4000 [rpm],
depending on subclass
• Value range
050 - 400 [rpm])
• Value range
010 – 700 [rpm]
• Value range
0010 - 1000 [rpm])
• Value range
00 - 10
• Value range
10 - 40 [rpm/ms]
• Value range
10 - 40 [rpm/ms]
• Value range
150-9999 [rpm]
• Value range
150-9999 [rpm]