Programming Commander DELTA
Icon
Parameter
Parameter Seam Begin
Needle thread clamp
The needle thread clamp is closed at
st
the 1
stitch of the seam to ensure that
the needle thread lies on the underside
of the sewing material
Seam begin bartack settings
Bartack at seam begin
Number of stitches backwards
Number of stitches forward
Number of bartack sections
A bartack consists of several sections.
If the sewing direction is changed, a
new section is started. The number of
sections in a bartack can be set here.
Stop-Time for direction
change
The waiting time at the turning points
(for example for a change of sewing
direction) is set at this point. A short
waiting time in milliseconds should
ensure consistent seam quality
(ornamental-stitch bartack)
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
5.6.4

Setting the Segment Begin parameters

There are various options for setting the Segment Begin
parameters. The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
Setting
Value range
On/Off
Value range
On/Off
Value range
01 - 50
Value range
01 - 50
Value range
01 - 99
Value range
0000 – 1000 [ms]