Adjusting feed dog and needle bar linkage

7.1 Adjusting the lateral feed dog position

Fig. 31: Adjusting the feed dog position
(1) - Feed dog
(2) - Feed dog carrier
To adjust the lateral feed dog position:
1. Execute the service routine Feed dog > Position to
 The software is used to define the necessary presettings on
2. Disassemble the throat plate ( p. 29).
3. Loosen the screws (3).
4. Move the feed dog (1) on the feed dog carrier (2).
5. Tighten the screws (3).
6. Assemble the throat plate.
7. Check the feed dog position and readjust it if necessary.
8. Finish the service routine.
Service Instructions M-TYPE DELTA - 00.0 - 12/2019
needle ( p. 14).
the machine.
Place the removed throat plate next to it as an aid for orientation so
that the feed dog (1) can be screwed on straight.
If this is not sufficient, move the entire feed dog carrier on the pusher
shaft ( p. 46).
(3) - Screws