Setting Machine-Specific Parameters - DURKOPP ADLER 867 Durkopp Adler

Hide thumbs Also See for 867:
Table of Contents

Advertisement

Setup
Operating Instructions 867 - 04.0 - 03/2018
Switch position on the circuit board
Fig. 76: Switch position on the circuit board
(1) - Switch
The position of the switch (1) depends on the subclass:
• Machines with a binder: Position 1
• Machines with switchable needle bars: Position 2
• Machines with a clean seam start:
 Additional Instructions 0791 867708

7.12.9 Setting machine-specific parameters

With DAC controls the parameters are automatically set via
transfer of the machine ID.
With Efka controls the parameter F-290 must be set for each
subclass according to the specifications in  Parameter sheet.
The parameter sheet is provided in the control accessory pack.
To set the machine-specific parameters:
1.
Set parameter F-290 according to the specifications in
 Parameter sheet.
For subclass 867-290342-100 only:
2.
Set parameter F-111 to 2500 min
p
-1
or less.
125

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents