03.06
F30659
Response:
Acknowledgement
Explanation
Remedy
© Siemens AG, 2006. All rights reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
SI MM: Write task for parameter rejected
OFF2
IMMEDIATELY (POWER ON)
The write task for one or several Safety Integrated parameters on the
Motor Module (MM) was rejected.
Note:
This fault does not result in a safety stop response.
Fault value (r0949, decimal):
10:
An attempt was made to enable the SH function although this cannot be
supported.
11:
An attempt was made to enable the SBC function although this cannot
be supported.
See also: r9771, r9871
Re fault value = 10, 11:
– Check whether there are faults in the safety function alignment
between the Control Unit and the Motor Module involved (F01655,
F30655) and if required, carry-out diagnostics for the faults involved.
– Use a Motor Module that supports the function safe standstill or safe
brake control.
– Upgrade the Motor Module software.
– Upgrade the Control Unit software.