Siemens SINUMERIK 840D sl Function Manual page 375

Sinumerik safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

03.06
Principle of operation – extended alarm text
If Alarm 27090 or Alarm 27254 occurs, the NCK transfers an additional parameter
value to the HMI software (27090: %4; 27254: %3). This parameter has a defined
value range. Each value can be uniquely assigned an extended alarm text.
Value range of the transfer parameter
000
Parameterizing error detected when booting (different state active)
Crosswise data comparison error, SPL protective mechanism: MD 11500 –
DB18.DBX36.0
Crosswise data comparison error, stop response for SPL error: MD 10097 –
DB18.DBX36.1
001...064
Error in system variables $A_INSE(P)[01...64] (Alarm 27090/Alarm 27254)
The index value then results from a channel error signaled from the PROFIsafe
module
(Alarm 27254), that is assigned the appropriate $A_INSE(P) variable (e.g. discrep-
ancy error)
065...128
Error in the system variables $A_OUTSE(P)[01...64] (Alarm 27090/Alarm 27254).
This means, Alarm 27090 signals an internal logic error ($A_OUTSE(P) variables
differ) and Alarm 27254 signals a channel error signaled from the PROFIsafe mod-
ule that is assigned to the appropriate $A_OUTSE(P) variable (e.g. short-circuit
fault).
129...192
Error in system variables $A_INSI(P)[01...64] (only alarm 27090)
193...256
Error in system variables $A_OUTSI(P)[01...64] (only alarm 27090)
257...320
Error in system variables $A_MARKERSI(P)[01...64] (only alarm 27090)
© Siemens AG, 2006. All rights reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition