Siemens SINUMERIK 840D sl Function Manual page 247

Sinumerik safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

03.06
13301
MD number
Standard value 0xFFFFFFFF
Change becomes effective after: Power ON
Data type: DWORD
Significance:
corresponds with...
Additional references
13310
MD number
Standard value 20
Change becomes effective after: POWER ON
Data type: DOUBLE
Significance:
corresponds with...
Additional references
© Siemens AG, 2006. All rights reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
$MN_PROFISAFE_OUT_FIL TER
F net (useful) data filter OUT
Min. input limit: –
Protection level: 7/2
Filter between $A_OUTSE variables and F net (useful) data
Machine data: PROFISAFE_OUT_ASSIGN is used to define which $A_OUTSE[n]
variables are transferred into the F net data bits of the PROFIsafe module.
Machine data: PROFISAFE_OUT_FILTER is used to define which F net data bit is
transferred to the particular $A_OUTSE[n] variable.
Example:
For reasons of simplicity, only 16 bits are taken into consideration.
Parameterization:
$MN_PROFISAFE_OUT_FIL TER = A944H
$MN_PROFISAFE_OUT_ASSIGN = 011006
n = 16
11
6
1
xxxx x111 111x xxxx
0000 0000 0011 111
1010 1001 0100 0100
1010 1001 0100 0100
$MN_SAFE_SPL_ST ART_TIMEOUT
Delay, display Alarm 27097
Min. input limit: 1
Protection level: 7/2
After the control has booted, after the time has expired, Alarm 27097 is displayed if there
was no SPL start. It is possible to completely suppress this alarm by changing MD
$MN_SAFE_DIAGNOSTIC_MASK, bit 1.
8.1 Machine data for SINUMERIK 840D sl
Max. input limit: –
example value in the $OUTSE variables, x not relevant
interal NCK F net data image
$MN_PROFISAFE_OUT_FIL TER
F net data of the PROFIsafe module
Max. input limit: 60
Data Description
Units: –
Units: s
8-247