Siemens SINUMERIK 840D sl Function Manual page 275

Sinumerik safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

03.06
36981
MD number
Default value: 0
Change becomes effective after: Power ON
Data type: DWORD
Significance:
Special cases, errors,...
Additional references
36982
MD number
Default value: 0
Change becomes effective after: Power ON
Data type: DWORD
Significance:
Special cases, errors,...
Additional references
© Siemens AG, 2006. All rights reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
$MA_SAFE_SS_ST ATUS_OUTPUT
Output assignment for SBH active
Min. input limit: –
Protection level: 7/2
This machine data defines the output or the system variable for the "SBH active" signal.
Structure: Refer to the coding of the output assignment
Signal
Means
= 0
SBH is not active
= 1
SBH is active
If MD bit 31 is set, then the signal is processed inverted.
Refer to MD 36980: $MA_SAFE_SVSS_DISABLE_OUTPUT
$MA_SAFE_VELO_ST ATUS_OUTPUT[n]: 0 ... 1
Output assignment active SG selection
Min. input limit: –
Protection level: 7/2
This machine data defines the outputs or the system variables for the signals "SG active bit
0" and "SG active bit 1".
Structure: Refer to the coding of the output assignment
n = 1, 0
stands for SG active, bits 1, 0
SG active
Bit 1
Bit 0
means
= 0
= 0
SG1 active, if SBH/SG is active and SBH is not active
SBH active, if SBH/SG are active and SBH is active
= 1
= 0
SG2 active
= 0
= 1
SG3 active
= 1
= 1
SG4 active
If MD bit 31 is set, then the signal is processed inverted.
Refer to MD 36980: $MA_SAFE_SVSS_DISABLE_OUTPUT
8.1 Machine data for SINUMERIK 840D sl
Max. input limit: –
Max. input limit: –
Data Description
Units: –
Units: –
8-275

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents