03.06
C01681
Response:
Acknowledgement
Explanation
Remedy
F01682
Response:
Acknowledgement
Explanation
Remedy
F01683
Response:
Acknowledgement
Explanation
Remedy
F01684
Response:
Acknowledgement
Explanation
© Siemens AG, 2006. All rights reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
SI motion: Incorrect parameter value
NONE
IMMEDIATELY (POWER ON)
The parameter value may not be parameterized with this value.
Fault value (r0949, decimal):
Parameter number with the incorrect value
Correct the parameter value.
SI motion: Monitoring function is not supported
OFF2
IMMEDIATELY (POWER ON)
The monitoring function enabled in p9501 is not supported in this
firmware version.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, decimal):
1:
Monitoring function SE (p9501.1)
2:
Monitoring function SN (p9501.7 and p9501.8 – 15 and p9503)
3:
Monitoring function SG override (p9501.5)
10:
Monitoring functions only supported in the servo mode.
De-select monitoring function involved (p9501, p9503).
SI motion: SBH/SG enable missing
OFF2
IMMEDIATELY (POWER ON)
In p9501, the safety-relevant basic function SBH/SG has not been
enabled although other safety-relevant monitoring functions have been
enabled.
Note:
This fault results in a STOP A that cannot be acknowledged.
Enable SBH/SG (p9501.0) and carry-out a power on.
SI motion: Safe software limit switch limits interchanged
OFF2
IMMEDIATELY (POWER ON)
For the function "safe software limit switch" (SE), in p9534 there is a
value less than that in p9535.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, decimal):