Procedure: WT Firmware Download and Connection
Table 4-2. WT Download Error Codes (continued)
Error Code
0x82
0x83
0x84
0x85XX
0x86
0x87
0x88
0x891
Severity
Description/Recommendation
Low
WT timed out waiting for the program data from
the RC.
For the 9601 WT, restart the download process.
For the 9630 Series WT, the download
automatically restarts; therefore, no user
intervention is required.
High
Download cable is not connected.
Connect the download cable between the RC
and the WT, and restart the download process. If
the cable is connected and the error continues to
occur, use another download cable.
High
Error while programming flash device.
Restart the download process. If the error
continues to occur, try a fully charged battery.
High
Flash memory erase error; reason XX.
Restart the download process. If the error
continues to occur, try a fully charged battery.
Low
WT timed out waiting for RC "info" message.
For the 9601 WT, restart the download process.
For the 9630 Series WT, the download
automatically restarts; therefore, no user
intervention is required.
High
RC wants to communicate at a bad baud rate.
Restart the download process.
High
RC wants to send a file in an unsupported
format.
Restart the download process.
High
The connected RC circuit pack is not enabled or
assigned as a server and is therefore disabled
from allowing WT upgrades.
Check the Feature-Related System Parameters
form at the bottom of page 2 for the RC circuit
pack. If the circuit pack is not listed, issue the
change system feature command and add it to
the list. Then issue the enable wt-upgrade
[PPCSS] command.