Wireless Fixed Base
4-pair cable routed from
110 hardware located in
equipment room to
103 connecting block
next to WFB.
(See the following
"103 Connecting Block"
figure.)
103 Connecting
Block
DW8A-DE
Cord
WFB
"A1"
From the transformer DW8A
cord jumper, connect the W/BR
(ground) pair to the W/BL-BL/W
pair of the 4-pair cable to the
WFB. Also connect the BR/W
(-48V) pair to the W/BR-BR/W
pair of the 4-pair cable to the
WFB. Doubling up the pairs
extends the power from the
power supply to the WFB
to 795 ft.
Place the dual jumper from the
WFB radio card port to the
W/O-O/W and W/G-G/W pairs of
the 4-pair cable to the WFB.
NOTE: See the following
"Cross-Connects
for WFBs" figure.
Figure 3-3. Typical Terminations and Cross-Connects for WFBs
Transformer (4) Each
PHONE
DW8A-SE Cord
103848800 terminates
all pairs on the 110
station hardware.
110AB2-300 Station
Four Pairs to WFB
1A
1B
2A
DW8A-SE Cords
TX1 TX2
TX3
110AC2-600 Switch Port Hardware
WFB Ports
1A
1B
Radio
Card "A"
2A
2B
Radio
Card "B"
Located Inside Equipment Room
LINE
OTHER
Avaya switch tech will
install this 103 jack.
Firmware
103 Connecting Block
Hardware
4-Pair Cable
To Firmware
2B
103 Jack
TX4
Place the 3-pair
jumper from the
firmware port to
the 4-pair cable
serving jack.
Firmware