Avaya DEFINITY Installation And Test page 15

Wireless business system
Hide thumbs Also See for DEFINITY:
Table of Contents

Advertisement

Procedure: Software Installation
display system parameters customer-options
Processor and System MSP? n
Restrict Call Forward Off Net? y
Station as Virtual Extension? n
Survivable Remote Processor? n
(NOTE: You must logoff & login to effect the permission changes.)
Figure 2-2. Optional Features Form (Page 4)
3. Change the Wireless field value from n to y.
4. Submit the form.
5. Log off and then log on again to the DEFINITY ECS local or remote MT as
init.
6. Execute the change system-parameters wireless command to generate
the Wireless System-Parameters form. Two versions of the form are shown
in the following figures:
OPTIONAL FEATURES
Private Networking? y
Remote Office? n
Secondary Data Module? y
Station and Trunk MSP? n
Page 4 of 10
Tenant Partitioning? n
Terminal Trans. Init. (TTI)? y
Time of Day Routing? n
Uniform Dialing Plan? y
Usage Allocation Enhancements? y
VAL Full 1-Hour Capacity? n
Wideband Switching? n
Issue 6 September 2001
Wireless? y
2-3

Advertisement

Table of Contents
loading