Confi gure the DeviceNet Scanner Subnet
This chapter describes how to custom confi gure your scanner for
use with H Series Fieldbus I/O modules.
See the Following Sections:
Confi guration Overview

Add the Scanner to Your Network

Add I/O Modules to Your Network

Set the Scanner's Parameters
Go On Line
Chapter Summary and What's Next
Your adapter works on two networks simultaneously and
must be confi gured for each separately. This chapter explains
confi guration of the scanner for use with H Series Fieldbus I/O
modules.
For information on how to confi gure the adapter for use on
the DeviceNet Network, see Chapter 5, Adding the DeviceNet
Adapters to the DeviceNet Scanner's Scanlist.
Confi guration Overview
You must use the RSNetWorx for DeviceNet software to confi gure
your scanner. You can confi gure the scanner while it is:
• On Line
• Off Line
This chapter shows confi guration in the offl ine mode. Confi guration
screens appear the same in both modes. Note that some screen
options are unavailable in offl ine mode. The only difference is that if
you make changes off line, you must take the scanner on line before
the confi guration changes take effect.
IMPORTANT
Throughout most of this manual, we refer to the H Series
Fieldbus I/O DeviceNet adapter as the adapter. The adapter
also communicates with Subnet modules as a scanner. In this
chapter only, the adapter is referred to as a scanner.
You must follow these steps during confi guration:
1. Add the scanner to your network
2. Add I/O modules to your network
3. Set the scanner's parameters
4. Go on line
Add the Scanner To Your Network
Follow these steps:
1. Start RSNetWorx for DeviceNet.
Page:
2. Add the scanner as shown below.
4-1
1. Expand the list of
4-1
Communication
4-1
Adapters.
4-2
4-6
4-6
Add I/O Modules To Your Network
After you add the scanner, you must add the modules connected to
the scanner on the Subnet. In the offl ine mode, I/O modules must
be added individually. Follow these steps:
1. Add modules as shown below.
1. Expand Vendor
Parker Hannifin Corp.
to display the list
of I/O modules.
Publication PSS-UM001A-EN-P – December 2016
Chapter
2. Select the PSSCDM12A
H Series Fieldbus
Scanner.
IMPORTANT
The scanner must always exist
on the Subnet at Node 00.
2. Double Click the
TIP: You can also
I/O module you
click and drag the
want to add to
module name onto
the network.
the network.
We used the PSSN8M12A,
PSST8M12A, and PSSNACM12A
I/O modules in this example. Your
network screen should refl ect the
I/O modules on your network.
4
3. The scanner
appears on
the network.