Install Devicebox Taps - Parker H Series Installation & Service Instructions Manual

Fieldbus system
Table of Contents

Advertisement

3-8
Make Cable Connections

Install DeviceBox Taps

Wire
Wire
Use
Color
identity
white
CAN_H
signal
blue
CAN_L
signal
bare
drain
shield
black
V-
power
red
V+
power
Publication DNET-UM072C-EN-P - July 2004
The DeviceBox tap contains terminal blocks that connect the trunk line and as
many as eight drop lines. It is used only with round media. Gland nuts secure
the cables entering the ports of the DeviceBox tap.To attach a DeviceBox tap:
1. Cut the required lengths from reels of trunk line using a sharp cable
cutter providing sufficient length in each segment to reduce tension at
the connection.
Cover the bare drain wire in the enclosure with the
IMPORTANT
insulating tubing supplied in the accessory kit.
2. Insert conductors into the terminal block clamping cavities, following
the color coding specified for the terminal blocks at the incoming and
outgoing thick cables and as many as eight thin cables.
thin cable terminal blocks
black
red
white
blue
drain
drain
blue
white
red
black
black
red
white
blue
drain
drain
blue
white
black
red
red
black
white
blue
drain
drain
white
blue
drop lines
black
red
(thin cable)
red
black
white
blue
drain
drain
blue
white
black
red
3. Tighten all clamping screws to secure conductors to the terminal blocks.
4. Seal unused ports with nylon plugs and nuts in the accessory kit.
5. Tightly secure the cover to the enclosure.
thick cable terminal blocks
trunk line
(thick cable)
plug
and nut
locking nut
hex flange
gland nut
trunk line
(thick cable)
drop lines
(thin cable)
plug and nut
41851