Class 1Auxiliary Power Cable
Spool size
Catalog number
75 m (246 ft)
1485C-P1L75
200 m (656 ft)
1485C-P1L200
420 m (1378 ft)
1485C-P1L420
Auxiliary Power Cable
Wire
Wire
Use
Color
identity
white
user
user
defined
defined
blue
user
user
defined
defined
black
V-
output
power
red
V+
output
power
3. Repeat the end cap installation process as outlined previously. Close the
IDC base and continue with connection as illustrated in the standard
installation instructions starting on page 3-10.

Install Class 1 KwikLink power cable

Install Class 1 KwikLink power cable as you would network cable. Refer to
page 3-10 for installation instructions. You can use auxiliary power cable
with the ArmorBlock MaXum cable base (1792D-CBFM) and I/O modules
(1792D series). When running cable into an enclosure, use flat cable gland
1485A-CAD.
.
red and black
dc power pair 16 awg
5.3 mm (0.21 in.)
white and blue
user defined pair 16 awg
30482
black PVC jacket
2.50 mm
(0.10 in.)
19.3 mm
(0.76 in.)
Publication DNET-UM072C-EN-P - July 2004
Make Cable Connections
3-15
30481
30483