WARNING
To avoid unpredictable system behavior that can cause personal injury
and property damage:
• Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
• Disconnect air supply and depressurize all air lines connected to
this product before installation, servicing, or conversion.
• Operate within the manufacturer's specified pressure, temperature,
and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• After installation, servicing, or conversion, air and electrical
supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is present,
or the product does not operate properly, do not put into use.
• Warnings and specifications on the product should not be
covered by paint, etc. If masking is not possible, contact your local
representative for replacement labels.
Safety Guide
For more complete information on recommended application guidelines, see
the Safety Guide section of Pneumatic Division catalogs or you can download
the Pneumatic Division Safety Guide at: www.parker.com/safety
Introduction
Follow these instructions when installing, operating, or servicing the
product.
isysNet 24 VDC Output Modules, Series A
(PSST8M23A, PSST8M12A, PSST8M8A, PSST16M23A,
PSST16D25A, PSST16M12A)
The sealed IP67 housing of these modules requires no enclosure.
(Note that environmental requirements other than IP67 may require
an additional appropriate housing.) I/O connectors are sealed M8
(pico) or M12 (micro) or M23 or 25-Pin D-Sub styles. The mounting
base ships with the module. The PSST8M23A, PSST8M12A,
PSST8M8A, PSST16M23A, PSST16D25A and PSST16M12A
modules are shown below.
PSST8M23A
Female
Connector
M23
Pneumatic Division
Richland, Michigan 49083
LED
Indicators
Installation & Service Instructions
E107P
isysNet 24 VDC Output Modules,
Series A (PSST8M23A, PSST8M12A,
PSST8M8A, PSST16M23A, PSST16025A,
PSST16M12A)
ISSUED: June, 2008
Supersedes: December, 2006
Doc.# E107P, EN# 080393, Rev. 3
PSST8M12A
Female
Connector
M12-A
Female
Connector
M12-C
PSST8M8A
Female
Connector
M8-A
Female
Connector
M8-C
Female
Connector
M8-E
Female
Connector
M8-G
!
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED
ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY
DAMAGE.
This document and other information from Parker Hannifin Corporation,
its subsidiaries and authorized distributors provide product and/or system
options for further investigation by users having technical expertise. It
is important that you analyze all aspects of your application, including
consequences of any failure and review the information concerning the
product or systems in the current product catalog. Due to the variety of
operating conditions and applications for these products or systems, the
user, through its own analysis and testing, is solely responsible for making
the final selection of the products and systems and assuring that all
performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features,
specifications, designs, availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION
IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS.
CONTACT YOUR LOCAL REPRESENTATIVE.
Female
Connector
M12-B
LED
Indicators
Female
Connector
M12-D
Female
Connector
M8-B
Female
Connector
M8-D
LED
Indicators
Female
Connector
M8-F
Female
Connector
M8-H

Advertisement

Table of Contents
loading

Summary of Contents for Parker A Series

  • Page 1 The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS.
  • Page 2: Important User Information

    (“Industrial Automation Wiring and Grounding Guidelines”), for additional installation requirements pertaining to this equipment. In no event will Parker Hannifin Corporation be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
  • Page 3: Mount The I/O Base

    isysNet 24 VDC Output Modules, Series A E107P Mount the I/O Base To mount the I/O base on a wall or panel, use the screw holes provided in the base. IMPORTANT The I/O module must be mounted on a grounded metal mounting plate or other conductive surface.
  • Page 4 isysNet 24 VDC Output Modules, Series A E107P Install the Digital Output Module PSST8M12A To Install the Digital Output Module, Proceed as Follows: 1. Using a bladed screwdriver, rotate the keyswitch on the mounting base clockwise until the number 1 aligns with the notch in the base.
  • Page 5: Communicate With Your Module

    Where: Channel Status 0 = no error, 1 = error; Output State 0 = OFF, 1 = ON 24VDC Common Common 24VDC Return 24VDC Common Common 24VDC Return EDS File Requirements 24VDC Common Common 24VDC Return 24VDC Common Common 24VDC Return The EDS files are available online at www.parker.com/pneu/isysnet.
  • Page 6 Add 24 VDC Output Modules to RSLogix If your RSLogic 5000 is Version 15.X or greater: 5000 I/O Configuration • Choose the PSST8M12A module from the list of Parker modules. To add your output modules to RSLogix 5000 I/O configuration, follow these steps: •...
  • Page 7: Troubleshoot With The Indicators

    isysNet 24 VDC Output Modules, Series A E107P Troubleshoot With the Indicators If your RSLogic 5000 is Version 13.X: • Choose the equivalent Rockwell Automation module from the list PSST8M12A of modules. Module Status Indicator Network Status Indicator I/O Status Indicators Indication Probable Cause Module Status...
  • Page 8: Specifications

    isysNet 24 VDC Output Modules, Series A E107P Specifications - Following are specifications for the digital output modules. Digital Output Modules Outputs per Module 8 (1 Group of 8) Non-isolated, Sourcing 16 (1 Group of 16) Non-isolated, Sourcing Voltage Drop, On-State Output, Maximum 0.2VDC (Sourcing Modules) 0.7VDC (Sinking Module) Voltage, Off-State Output, Maximum...

This manual is also suitable for:

Psst8m23aPsst8m12aPsst8m8aPsst16m23aPsst16025aPsst16m12a

Table of Contents