HONDA
'82 ADDENDUM
CXSOO
Install the pulse generator assembly aligning
the steel core on the coil case with the rotor
tooth.
Tighten the screws securely.
Rotate the crankshaft clockwise, and align the
"FS'mark on the "TC' (left) side with the index
mark on the rear cover. Check that the rotor
tooth is aligned with the steel core on the lower
coil case.
Check the air gap between the rotor tooth and
the steel core.
AIR GAP: 0.40-0.70
m m
(0.016-0.028 in)
ALIGNING THE
$TriEL
CORE WITH
THE ROTOR TOOTH
For air gap adjustment, refer to page 25-22.
Install the pump impeller, water pump cover
and water pipe.
Install the pulse generator cover.