C X 5 0 0
STARTER MOTOR
STARTER MOTOR
b
REMOVAL
m m
I
It'rrll
iilc
i,enition switch OFF, remove
I
the negative cable at the battery before
servicinr the starter motor.
STARTE
Remove the starter motor case screws. Inspect
the brushes and measure brush length. Measure
brush spring tension with a spring scale.
SERVICE LIMITS:
Brush length: 5.5
mm
(0.21 in.)
Brush spring tension: 400
g
BOLTS
Remove the starter mounting bolts and pull the
:
motor out of the engine case.
,~.
Disconnect the starter cable.
L
...
BRUSH INSPECTION
7
. . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
. . .
. .
9
COMMUTATOR INSPECTION
Remove the case.
-
NOTE
Record the location and number of the
thrust washers.
Inspect the commutator bars for discolora-
tion.
Bars discolored in pairs indicate grounded
L
armature coils.
NOTE
Do not use emery or sand paper on the
commutator.