Step
5
6
7
8
9
Sensors cannot be walk-tested unless the sensor's point type, group, gateway, and Hard ID are in the
control unit's database.
GATEWAY
TRUNK
CONNECTIONS
+12V
GND
COM ( ) +
COM ( )

Figure 5-7: SIM Wiring to System-Powered and Nonpowered Sensors

5-18
Action
Snap the Trunk Junction box SCN 148320 around the connections to enhance
appearance.
Connect the branch cable to the SIM or SIM Sensor. SIM sensors that have screw
terminals include the smoke detector, the FA Pullbox, motion sensors, and the
horn/strobe. Connect these directly to the branch cable.
Splice the SIM module to the branch cable. Use SCN 810953 connectors to splice to the
branch cable.
Collect the point description, gateway number, and Hard ID's of all installed SIMs so
they can be programmed into the control unit. Use the Gateway Trunk Log Form to
record the Gateway, Hard ID, BA Group, and point description. Once the data has been
collected, it must be entered into the control unit via the operating panel. See the
Programming section for the procedure. Once the data has been programmed, any walk-
tests LEDs will function.
The Hard ID label: The top line is the barcode. The second line is in readable text. The
first eight digits are the Hard ID. The next six digits are the Stock Code Number (SCN
#). The next four digits are the manufacturing date codes ("year week"). The last two
digits are for the vendor codes like "P" for Pine Brook.
Mark the SIM Sensor point number stick-on labels SCN 146844. Peel off the number
that represents the point number and stick it on the outside of the sensor so it is clearly
visible and can be referred to later.
472366 SIM
OUT 0
RED
TRANSISTOR
BLK
SWITCH
BLU
+12V
IN 0
C5
2.3 uf
25V
IN 2
YEL
IN 0
MICROPROCESSOR
INPUT
IN 2
MICROPROCESSOR
OUT 0
OUTPUT
OUTPUT POWER
RED-WHT
+12V
(FOR INPUT POINT, TRANSISTOR SWITCH IS
CONTINUOUSLY CLOSED TO SUPPLY SENSOR POWER.
BLK-WHT
FOR OUTPUT POINT, TRANSISTOR SWITCH CLOSES ONLY
GND
WHEN COMMANDED FROM CONTROL UNIT.)
SYSTEM-POWERED
SENSOR
W/ TRANSFER CONTACTS
AND TAMPER
+12V
GND
ORG
AL-TBL
T
BLU-WHT
TMPR
WHT
CONDITION IN 0 IN 2
NORMAL
6V GND
ALARM
GND GND
TAMPER
6V
12V
OPEN LOOP 12V 12V
NON-POWERED
SENSOR
W/ BREAK-ONLY CONTACT
(NO TAMPER)
CONDITION IN 0 IN 2
NORMAL
6V GND
ALARM
12V GND
TAMPER
6V
12V
OPEN LOOP 12V 12V