ADT FOCUS 200 PLUS Installation And Setup Manual page 101

Commercial fire and burglary security system with scheduling
Hide thumbs Also See for FOCUS 200 PLUS:
Table of Contents

Advertisement

Entry
Description
Number
64 (EXP)
Exit
Pushbutton
Person Without Janitor Privilege
User Action
Person leaving presses
pushbutton.
Person exits, closes the
door, and uses the coded
key/card.
Person exits, closes the
door, but forgets to use
the coded key/card.
Person With Janitor Privilege
User Action
Entry
Janitor uses the coded
key/card and unlocks the
door
Exit
Janitor exits and presses
the pushbutton.
Janitor exits and presses
the pushbutton, closes
the door, uses the coded
key/card (or Janitor
Keyswitch).
Janitor closes the door,
but forgets to use the
coded key/card (or
Janitor Keyswitch.
Function
This point type uses a RPX-264 Pushbutton, installed inside of the
access-controlled area, to establish a 1-minute exiting-time window
for the last person leaving. This allows the person time to open the
door, exit, and use a coded key at a Keylok to lock the door, thereby
automatically tuning on the BA groups.
The pushbutton is ordinarily connected to a SIM. However, for
retrofit purposes, the pushbutton can also be connected to a 471999
Switch Interface Module.
When someone with a Janitor privilege uses the pushbutton for
exiting, then closes the door and uses the coded key to lock the
Keylok, the shunt is removed from all Janitor points that were alarm
shunted. Also, a Janitor Off Premises signal is sent to the CCC.
The LED option serves to annunciate the exit delay. See the tables
below for the status indications for a person with and without Janitor
privilege during entry and exit.
BA Groups
LED Status
Status
Off
Off
Normal
Begins flashing (1-sec
On/1-sec Off).
Not Ready
Off
Normal
On Steady.
Not Ready
Off
Normal
Goes Off at the end of
1-minute time window.
BA Groups
LED Status
Status
On
On
Normal
Slow flashing (1-sec
On/2-sec Off).
Normal
Changes from slow to
fast flashing (1-sec
On/1-sec Off).
Not Ready
Remains slow flashing.
Normal
Changes to On steady.
Normal
At end of 1-minute
window, slowly flashes.
Section 10 – Access Control
Result
Indicates BA groups are Off.
1-minute window starts.
1-minute window does not start.
Indicates BA group(s) are On and door can
now be locked.
BA group(s) will not turn On. (Where
Keylok is involved, person will not be able
to turn key to lock the door.)
Indicates BA groups are Off.
Result
Indicates BA groups are On.
Indicates janitor points in all BA groups
have become alarm shunted.
1-minute window starts.
Indicates BA groups are not normal.
Indicates alarm shunt has been removed
from each janitor point in system and BA
groups are On. Door can now be locked.
Indicates BA groups are On, but Janitor
points in each group are still alarm
shunted.
10-15