To test the LCD display:
Step
1
2
3
4
5
6
7
8

Local Tests

The local tests are typical of a local-only system because they do not involve the CCC. Perform a system
test by activating each sensor, in turn, and verifying that the alarm condition is properly displayed on
the operating panel(s), and that the panel sounder functions properly. Indicate the results on the
appropriate ADT form. Inspect the system performing the various tests and battery check. If problems
are encountered, troubleshoot and repair as needed.
Before performing the Burg pts audibly test (described in Additional Test Options), all points to be
tested in this mode must be bypassed.
Enter the Service Code and then proceed as follows:
< ?
< Lesson
< See alarms
< Quit
< ?
< See points
<
< Previous
< ?
< Quit
When any of the Local Tests are selected, the sensitivity of the RF receiver is reduced by approximately
50%, if RF points are programmed in the system.
20-2
Action
Enter the operating panel test mode by pressing the [1] and [8] keys simultaneously. The
system displays the operating panel and system information.
Once "WAIT" is displayed, enter the operating panel code (1, 2, 3).
Press the Test LCD selector button. All the pixels on the display screen light up.
Press any key. The screen goes blank.
Press any key. All alphabetic characters and numbers are displayed.
Press any key. The keypad test screen is displayed.
Press Quit to return to the operating panel and system information screen.
Press Quit again to return the normal operation screen.
Action Menu #1 is displayed.
Enter choice:
Select More.
Turn on >
Reset >
More >
Action Menu #2 is displayed.
Enter choice:
Test >
Select Test.
Change close time >
More >
The Test Screen is displayed.
Test:
Burglary groups >
Select Burglary groups to test a particular BA Group.
Sensor points >
Select Sensor points to test particular types of points within a BA
More >
Group.
Select More to display additional test options (Bell & Display and
Burg points audibly).
Select Quit to return to Action Menu #2.