Wolf COB-2 Operation Instructions Manual page 44

Oil condensing boiler for central heating with stratification cylinder
Table of Contents

Advertisement

Installation
Fig. 5.23
Terminal box electrical connection
Power supply 230 V
q
Z1 supply 230 V
w
Feed/heating circuit pump
e
Cylinder primary pump (PP)
r
A1 programmable output
t
Terminal assignment in terminal box
Fig. 5.24
Terminal box terminal assignment
Terminal
Mains
Z1
ZHP (FHP)
44 | WOLF GmbH
q w e
230VAC
Netz
Z1
L1
L1
L1
Explanation
Power supply
230 V output when ON/OFF switch is in the ON position
Maximum of 1.5 A per output, no more than 600 VA in total
Feed / heating circuit pump control
Maximum of 1.5 A per output, no more than 600 VA in total
r t
y
u i o
E1 programmable input
y
E2 common sensor
u
Outside sensor
i
Cylinder sensor
o
eBus
a
ZHP
A1
LP
N
L1
N
L1
a
≤ 24 V
E1
E2
E2
AF
SF
eBUS
-
a b
a b
a b
1 2
1 2
+
1 2
1 2
1 2
1 2
1 2
3066501_201910