3
2
1
: Disconnect the short circuit
wire (1).
: Take out the screws (2).
: Remove the ground wire (3).
– Remove the ignition module.
1
3
: Pull the grommet (1) off the
ignition module.
: Unscrew the ignition module (3)
from the ignition lead (2).
– Check the spark plug boot and
ignition lead, and replace if
necessary, b 7.5
50
– Troubleshooting, b 3.5
– Before installing the ignition lead,
fill the high voltage output with
STIHL multipurpose grease
b 15.
2
Do not use either graphite grease or
silicone insulating paste.
– Reassemble in the reverse
sequence.
Make sure the grommet (1) is fitted
properly to avoid ignition system
problems that may be caused by
contamination or moisture.
Installing
Machines with Heating
2
Before installing the ignition
module, check that the generator
wire (arrows) is properly positioned,
b 13.7.
1
2
: Fit the ignition module (1) and
insert the screw (arrow)
– do not tighten down yet.
: Fit the ground wire (3) and insert
the screw (2) – do not tighten
down yet.
Crimped side of terminal must face
the screw head.
1
: Push the ignition module back
and slide the setting gauge (1)
1111 890 6400 between the arms
of the ignition module and the
flywheel magnet.