3.4.11 Server trigger on "Measurement series reaches limit value"

Function description
Any actions can be initiated if at least one of them has exceeded the limit value in
one of the measurement series configured in the trigger.
The trigger is only initiated if a limit value is violated at the point of the axis test.
Subsequent modification of the limit values to below the violation limit does not
trigger any actions.
Fig. 3-38: Trigger on measurement series reaches limit value
Function
Name
Initiate trigger if
a measurement
© Siemens AG 2012 All Rights Reserved
ePS Network Services, Function Manual (FH) - 03/2012
Description
Name for the trigger; can be entered by the
user. If the field remains empty, or the
name is deleted, ePS Network Services will
generate a name from the selected meas-
urement ranges. A consecutive number (n)
can be added to this.
Select type of limit value
 "reaches the critical limit"
If at least one critical limit has been
reached or exceeded.
 "reaches the warning limit or the critical
limit"
If at least one warning limit has been
reached or exceeded, whereby the criti-
cal limit may also have been exceeded.