Fig. 3-36: Combinable triggers
Function
Name
Trigger
event
tolerance
Notice
If the next trigger is triggered before execution of the diagnostics actions is com-
pleted (e.g. save data), the diagnostics actions, e.g. record data, cannot be exe-
cuted as parallel trigger evaluation is not possible. The missing of the trigger and
of course the data for this type of event cannot be prevented by the system.
The repeat frequency is generally less than one second, with high interface
demands it may be a few seconds.
© Siemens AG 2012 All Rights Reserved
ePS Network Services, Function Manual (FH) - 03/2012
Description
Name of the trigger; can be entered by the user.
If the field remains empty or is deleted, the sys-
tem generates a name from the parameters of
the trigger. The name varies according to the
screen resolution.
If the name already exists, a consecutive num-
ber is automatically added in parentheses.
If the name is too long, the number added can
only be seen in a tooltip.
Time to be bridged between successive initiation
of individual triggers and initiation of a total trig-
ger.
Adding or changing any number of triggers until
the limitation by the PLC data block can be
ANDed. See also: PLC performance index
3 Setting up functions
3.4 Fault services
Type
DISPLAY
INPUT
(max. 40 char-
acters, all
characters are
permissible)
DISPLAY
INPUT
SELECTION
(Time values
between 500
ms and 24
hours are
possible.)
DISPLAY
ACTION
SELECTION
3-139