Mounting of FH-L Series
• Make sure to tighten all screws in mounting.
• For good ventilation, provide a clearance of 50 [mm] or more above the Sensor Controller away
from other devices in the normal floor mounting. For the right and left sides, provide a clearance of
30 [mm] or more, and for the back side, 15 [mm] or more. These clearances are also required when
mounting multiple Sensor Controllers side by side. For the back mounting, the back-side clearance
of 15 [mm] is not required.
• Do not install the product immediately above significant heat sources, such as heaters, transform-
ers, or large-capacity resistors.
• Do not install the Sensor Controller in a cabinet with high-voltage equipment installed.
• Mount the Sensor Controller at 200 [mm] or more from power cables apart.