5-3

Sensor Controller Installation

5-3-1

All Series

Precautions for Safe Use
Power Supply and Wiring
• Make sure to use the product with the power supply voltage specified by this manual.
• Provide the power from a DC power supply (safety extra-low voltage circuits) that has been
taken measures not to generate high-voltage.
• Make sure to tighten all screws in mounting.
5-3-2

FH-1000/2000/3000/5000 Series

Precautions for Safe Use
Power Supply and Wiring
• Keep the power supply wires as short as possible (Max. 2 m).
• Use the wire of a suitable size (AWG 10 to 16) according to the current consumption.
Ground
• The power supply circuit of the FH Sensor Controller is insulated from the internal circuit.
• When a base is packed in a camera that will be connected to the Sensor Controller, make
sure to mount the camera using the base. Since the enclosure of the camera body is con-
nected to the internal circuits, the circuits may cause short-circuit with FG if the base is not
used to mount the camera and result in malfunction or damage.
• Apply Class D grounding (grounding resistance: 100 [Ω] or less)
• Provide the grounding point as close to the product as possible to shorten the grounding wire.
• Wire the grounding wire for the Sensor Controller independently. If the grounding wire is
shared with other devices or connected to a building beam, the Sensor Controller may be ad-
versely affected.
Connect the FH-1000/2000/3000/5000 Series to FH-MT12
Do not ground the positive terminal of the 24 VDC power supply when connecting the Sensor
Controller and FH-MT12 using a USB cable. The internal circuits may cause a short-circuit and
result in malfunction.
Connect the FH-1000/2000/3000/5000 Series to FH-SC12/FH-SM12 (12 megapixels cam-
era)
Do not ground the positive terminal of the 24 VDC power supply when connecting the Sensor
Controller and a 12 megapixels camera like FH-SC12 or FH-SM12.
Precautions for Correct Use
When connecting the sensor controller and monitor with a switcher and splitter
Do not use devices that may require re-recognition of the monitor by the Sensor Controller
when a switching operation was performed. If such re-recognition processing happens at
switching operation, it may cause measurement time to be longer.
FH Series Vision System Hardware Setup Manual (Z366-E1)
5 Setup and Wiring
5 - 5
5