5-3-3

FH-L Series

Precautions for Safe Use
Power Supply and Wiring
• Keep the power supply wires as short as possible (Max. 2 m).
• Use the wire of a suitable size (AWG 10 to 16) according to the current consumption.
• Recommended power source for FH-L series: OMRON S8VK-G£££24 or S8VS-£££24.
Ground
• The power supply circuit of the Sensor Controller is not insulated from the internal circuit.
• When a base is packed in a camera that will be connected to the Sensor Controller, make
sure to mount the camera using the base. Since the enclosure of the camera main body
made of metals is short-circuited with the internal circuit, the internal circuit might be short-
circuited with FG if no base is used, so that failures or malfunctions may be caused.
• Apply Class D grounding (grounding resistance: 100 [Ω] or less)
• Provide the grounding point as close to the product as possible to shorten the grounding wire.
• Wire the grounding wire for the Sensor Controller independently. If the grounding wire is
shared with other devices or connected to a building beam, the Sensor Controller may be ad-
versely affected.
Connect the FH-L series Sensor Controller to the FH-MT12 Touch panel monitor.
Do not ground the positive terminal of the 24 VDC power supply when connecting the Sensor
Controller and FH-MT12 using a USB cable. The internal circuits may cause a short-circuit and
result in malfunction.
When connect the FH-L series Sensor Controller to the FH-SC12/FH-SM12: 12 megapix-
els camera
Do not ground the positive terminal of the 24 VDC power supply when connecting the Sensor
Controller and a 12 megapixels camera like FH-SC12 or FH-SM12.
Connection of Terminal Block of FH-L Series
Connect to the terminal block by using the terminal connector, male: FH-XCN-L, which is packaged
with Sensor Controller.
Use the wire of a suitable size (AWG 12 to 16) according to the current consumption. Keep the power
supply wires as short as possible: Max. 2m.
1
Insert the end of the signal line, electric wire, into the terminal block connector (male). Tighten
the three screws on the connector top to secure the wire. Recommended tightening torque: 0.5
to 0.6 N•m
2
Insert the terminal block connector (male) into the terminal block connector (female) on the FH
Sensor Controller side.
Power Terminal Con-
FH Series Vision System Hardware Setup Manual (Z366-E1)
nector
+
Connect to the DC output terminal +V of 24 VDC.
-
Connect to the DC output terminal -V of 24 VDC.
Connect to the earth.