Line voltage ...............................................................................................................100 to 240 V ±10 %
Line frequency .........................................................................................................................50 to 60 Hz
Power consumption of Axioskop 2 plus ......................................................................................... 150 VA
Power consumption of Axioskop 2 mot plus .................................................................................. 170 VA
HBO 100 W transformer (HBO 100 W/2 and HBO 103 W/2)
Operation ..............................................................................................................................closed rooms
Protection class......................................................................................................................................... I
Enclosure protection .......................................................................................................................... IP 20
Line voltage .....................................................................................................................100 to 240 VAC
Line frequency .........................................................................................................................50 to 60 Hz
Power consumption when HBO 103 is used................................................................................... 155 VA
HBO 50 transformer mbq52ac-z
Operating environment.............................................................................................................clean room
Protection class......................................................................................................................................... I
Protection type .................................................................................................................................. IP 20
Line voltage can be changed between .................................. 100, 110, 120, 127 VAC and 230, 240 VAC
Line frequency can be changed between .............................................................................. 50 and 60 Hz
Power consumption when HBO 50 is used.............................................................................max. 350 VA
Fuses in accordance with IEC 127
Axioskop 2 plus microscope stand .................................................................................T 4 A/H, 5x20 mm
Axioskop 2 mot plus microscope stand ..........................................................................T 4 A/H, 5x20 mm
HBO 50AC transformer mbq52ac-z ........................................................................100 V, 127 V: 2x T 4 A
.......................................................................................................................
HBO 100 W transformer .............................................................................................T 2.0 A/H, 5x20 mm
Light sources
Halogen illuminator .......................................................................................................HAL 12 V / 100 W
Adjustment of the light source ....................................................................... continuous, 3 to 12 V
Mercury pressure short-arc lamp.......................................................................................... HBO 103 W/2
Power consumption for HBO 103 W/2................................................................................... 103 W
B 40-075 e
10/03
INSTRUMENT DESCRIPTION
Technical data
Change of line voltage is not required!
220 V to 240 V: 2x T 2.5 A