National Instruments 653 Series User Manual page 74

For traditional ni-daq. high-speed digital i/o devices for pci, pxi, compactpci, at, eisa, and pcmcia bus systems
Hide thumbs Also See for 653 Series:
Table of Contents

Advertisement

ACK
REQ
Input Data Valid
(REQ-edge
Latching)
Input Data Valid
(REQ-edge
Latching Disabled)
Parameter
Input Parameters
t
REQ pulse width
rr*
t
REQ inactive duration
r*r
t
ACK to next REQ
ar
t
Input data setup to REQ active
dir(1)
(with REQ-edge latching)
t
Input data hold from REQ active
rdi
(with REQ-edge latching)
t
Input data setup to REQ
dir(2)
(with REQ-edge latching disabled)
t
Input data hold from ACK
adi
(with REQ-edge latching disabled)
Output Parameters
t
ACK pulse width
aa*
t
REQ to ACK inactive
ra*
All timing values are in nanoseconds.
With REQ-edge latching enabled (default), the REQ edge determines when data is
Note
latched. Input data valid has to be held before the active-going REQ edge a minimum of
t
ns. With REQ edge disabled, input data valid has to be held t
rdi
active-going ACK signal edge is asserted.
© National Instruments Corporation
t
aa*
t
ra*
t
ar
t
r*r
t
t
dir(1)
rdi
t
dir(2)
Description
Figure 3-16. Level-ACK Input Timing Diagram
3-19
Chapter 3
t
rr*
ACK and REQ are shown as active high.
Minimum
75
75
0
0
10
0
0
225
100
after the next
adi
NI 653X User Manual
Timing Diagrams
t
adi
Maximum
200

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

65346533

Table of Contents