National Instruments 653 Series User Manual page 76

For traditional ni-daq. high-speed digital i/o devices for pci, pxi, compactpci, at, eisa, and pcmcia bus systems
Hide thumbs Also See for 653 Series:
Table of Contents

Advertisement

ACK
REQ
Output Data Valid
(REQ-edge
Latching)
Output Data Valid
(REQ-edge
Latching Disabled)
Parameter
Input Parameters
t
REQ pulse width
rr*
t
REQ inactive duration
r*r
t
ACK to next REQ
ar
Output Parameters
t
ACK pulse width
aa*
t
REQ to ACK inactive
ra*
t
REQ inactive to new output data
r*do
(with REQ-edge latching)
t
REQ to new output data
rdo
(with REQ-edge latching disabled)
t
Output data valid to ACK
doa
(with REQ-edge latching disabled)
1
t
(min.) = 25 + programmable delay
doa
Note
With REQ-edge latching disabled (default), output data valid holds t
REQ edge is asserted. With REQ-edge latching enabled, that data is held for at most t
after the REQ edge deasserts.
© National Instruments Corporation
t
aa*
t
rdo
t
ar
t
r*r
t
ra*
t
doa
Description
Figure 3-19. Level-ACK Output Timing Diagram
3-21
Chapter 3
t
t
rr*
rdo
t
r*do
ACK and REQ are shown as active high.
Minimum
75
75
0
225
100
0
0
1
25
NI 653X User Manual
Timing Diagrams
Maximum
200
50
ns after the
rdo
ns
rdo

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

65346533

Table of Contents