National Instruments 653 Series User Manual page 111

For traditional ni-daq. high-speed digital i/o devices for pci, pxi, compactpci, at, eisa, and pcmcia bus systems
Hide thumbs Also See for 653 Series:
Table of Contents

Advertisement

Using the Schottky-Diode Termination Scheme
© National Instruments Corporation
You can terminate a cable that acts as a uniform transmission line in several
ways. If your NI 653X is driving a cable, use the following termination
scheme: connect two Schottky diodes to each line, one to +5 VDC and the
other to ground. This termination clamps any overshoot or undershoot that
occurs. The +5 V and ground connections should be low-impedance
connections. For example, if you make your +5 V connection through a
long wire, back to the +5 V pin of the NI 653X, add a capacitor to your
termination circuit to stabilize the +5 V connection near the Schottky
diodes.
One suitable Schottky diode is the 1N5711, available from several
manufacturers. For more specialized use, you may be able to find diodes
packaged in higher densities appropriate to your application. For example,
the Central Semiconductor CMPSH-35 contains two diodes, suitable for
terminating one line. The California Micro Devices PDN001 contains
32 diodes, suitable for terminating 16 lines.
You do not need to add diodes to terminate the input signals. The NI 653X
contains onboard Schottky diode termination. Figure D-5 illustrates
transmission line terminations.
Appendix D
D-7
Hardware Considerations
NI 653X User Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

65346533

Table of Contents