ERX 7.0.x Hardware Guide
To remove a line module, SRP module, or SRP I/O module:
1.
2.
3.
4.
Figure 24: Ejectors in the Closed Position
5.
6.
46
Removing a Line Module, SRP Module, or SRP I/O Module
For SRP modules and SRP I/O modules, issue the appropriate halt command
(halt, halt primary-srp, or halt standby-srp).
See JUNOSe System Basics Configuration Guide, Chapter 5, Managing Line
Modules and SRP Modules for information about the halt commands.
Ground yourself by using an antistatic wrist strap or other device.
Use a screwdriver to loosen the thumb screws located at the top and bottom of
the module panel.
Pull the ejector handles located at the top and bottom of the module so that
they are in position 2, as shown in Figure 24.

Opened
Œ
Closed
Œ
Closed

Opened
Carefully slide the module out of the chassis.
Place the module in its antistatic bag.