Figure 41: SODIMM Sockets on the SRP-5 and SRP-10 Module
Cream ceramic connector
Empty SODIMM socket
SODIMM
Figure 42: SODIMM Sockets on the SRP-40 Module
2.
3.
88
Upgrading Memory on SRP Modules
NVS card
Empty SODIMM socket
SODIMM
Insert a SODIMM from the upgrade kit at an angle of approximately 45 degrees
into an empty ceramic connector, so that the notch in the long gold edge of the
SODIMM aligns with the notch in the connector.
The notch on the long gold edge will no longer be visible when the SODIMM
is pressed in far enough.
Press the top surface downward into the socket until the socket spring snaps
into place and holds it.
1. Align notches in
SODIMM and connector.
2. Push SODIMM into
connector at an angle of
approximately 45 degrees.
3. Push down on back edge
of SODIMM until it snaps
into socket.