Mounting Cut-Out

5.6.3

Mounting Dimensions VAM 12.1

To mount the control panel, proceed as follows:
1. Create a mounting cut-out with 6 holes, cross-section 4.5 mm according
to
fig. 5-11 "Mounting dimensions VAM 12.1" on page 41
"Mounting dimensions VAM 42.1" on page
2. Insert the control panel from the front into the cut-out. Then insert the
mounting bolts M4 into the drilled holes.
3. Fasten the control panel by screwing the nuts at the rear side of the
mounting bolts.
NOTICE
The tightening torque for M4 nuts (1.4 Nm) must not be exceeded.
Hole for threaded bolts
240
225
7.5
167.5
7.5
Fig.5-11:
Mounting dimensions VAM 12.1
Bosch Rexroth AG
Dimensions and Installation
42.
Damage to the mechanics due to incorrect
tightening torque.
Mounting cut-out
215 x 324
167.5
350
41/93
and
fig. 5-12