DOK-SUPPL*-VAM*XX.1***-PR02-EN-P
Rexroth IndraControl VAM 12.1/42.1 Machine Control Panels
7.9.4

X2.1: STOP Button VAC 30.2

Pin Assignment

7.9.5

X2.2: Enabling Button VAC 30.2

Pin Assignment X2.2

DANGER
⇒ The DC 24 V input voltage must comply with the requirements of the "Pro‐
tective separation"!
⇒ Plug and unplug the connector only if there is no voltage!
Interfering AC voltage components such as the ones resulting from an uncon‐
trolled three-phase bridge circuit without smoothing and with a ripple factor (see
DIN 40110/10.75, section 1.2) of 5 % are allowed.
That results in the greatest absolute value of 30.2 V as upper voltage limit. The
lowest obsolete value of 18.5 V is the lower voltage limit.
Pin
X2.1 pin1
X2.1 pin2
X2.1 pin3
X2.1 pin4
Fig.7-26:
Pin assignment of the STOP button VAC 30.2 X2.1
The circuit of the STOP button might be operated with a maximum
of 30 V and has to be protected with a 2-A-fusible cut-out.
DANGER
The circuit of the STOP button or EMERGENCY STOP button might be oper‐
ated with a maximum of 30 V and must be protected with a 2-A-fusible cut-out.
Pin
X2.2 pin1
X2.2 pin2
X2.2 pin3
X2.2 pin4
Fig.7-27:
Enabling button X2.2
DANGER
The circuit of the enabling device might be operated with a maximum of 30 V
and has to be protected with a 2-A-fusible cut-out.
Bosch Rexroth AG
Danger without protective separation!
Signal name
STOP button 1 IN
STOP button 1 OUT
STOP button 2 IN
STOP button 2 OUT
Risk of injury due to malfunction of the STOP
button or EMERGENCY STOP button.
Signal name
Enabling button 1 IN
Enabling button 1 OUT
Enabling button 2 IN
Enabling button 2 OUT
Risk of injury due to malfunction of the enabling
button.
67/93