DOK-SUPPL*-VAM*XX.1***-PR02-EN-P
Rexroth IndraControl VAM 12.1/42.1 Machine Control Panels
7.5.2
Pin Assignment (3 × 8-Pin Weidmüller Connector, 3.5 Pin Spacing)
Connector
Pin
Signal
X21
1
I0
2
I1
3
I2
4
I3
5
I4
6
I5
7
I6
8
I7
X22
1
I8
2
I9
3
I10
4
I11
5
I12
6
I13
7
I14
8
I15
X11
1
Q0
2
Q1
3
Q2
4
Q3
5
Q4
6
Q5
7
Q6
8
Q7
Fig.7-12:
Pin assignment X21, X22, X11
NOTICE
Use only copper wire (24 to 14 AWG) for wiring the connection terminals.
DANGER
The connectors for the inputs and the outputs must not be connected or dis‐
connected under load.
Bosch Rexroth AG
Meaning
Digital 24 V inputs I 0 – I 7
Digital 24 V inputs I 8 – I 15
Digital 24 V outputs Q 0 – Q 7
Insufficient contact and loss of UL certification
if inadequate wire is used.
Dangerous movements caused by plugging or
unplugging connectors under load!
59/93
Interfaces