5.2.2

Mounting Cut-out

Mounting the operator panel
and Controls
Avoid installation locations exposed to direct sunlight, as additional heat
development can occur.
Install the operator panel in a manner ensuring easy access to the front
panel (top side).
Lay all connecting cables in loops and use strain reliefs for all cables.
Keep as much distance as possible to noise sources.
To mount the operator panel proceed as follows:
1.
Create a mounting cut-out with 8 holes, diameter: 4.5 mm...
2.
Insert the operator panel from the front into the cut-out. Then insert the
mounting bolts M4 into the drilled holes.
3.
Fasten the operator panel by screwing the nuts at the rear side of the
mounting bolts.