Air Interlock Switch Removal And Replacement - Thermador Pro Grand PRD304EG Service Manual

Hide thumbs Also See for Pro Grand PRD304EG:
Table of Contents

Advertisement

Service Manual for Thermador Pro Grand Dual Fuel Ranges:
4. At the back of the range, detach the wire connectors, and make a
note of which wires are connected to each of the two different
terminals (see Figure 140, page 72).
NOTE: It is always recommended to label and tag all wires, wire
connectors and harnesses prior to disconnecting them, so as to
correctly identify their connections/locations when re-assembling.
Alternatively, you can photograph the wire connections prior to
disconnecting (for example, with your mobile phone).
5. Remove and retain the screws that secure the cooling fan
mounting plate onto the range chassis (see Figure 139).
6. Using gloves, remove the cooling fan.
7. Replace the cooling fan if needed.
Figure 140: Typical Cooling Fan
1
Wire connectors (2)
58300000157422_ARA_EN_A
PRD304EG, PRD364EDG, PRD364EDPG, PRD364ELG, PRD366EG, PRD366EPG, PRD484ECG, PRD484EEG, PRD486EDG, PRD486EDPG, PRD486ELG
4.6.6.1

Air Interlock Switch Removal and Replacement

The air interlock switch can be removed and replaced independently
of the cooling fan.
Be sure to check QuickFinder for relevant information, documentation,
and the correct part number when replacing this component.
Figure 141: Air Interlock Switch
Figure 142: Bracket
1. Follow all safety precautions and steps in Preparing the Range for
Servicing, page 21.
2. Remove the backguard, per Backguard and Island Trim Removal
and Replacement procedure, page 68.
3. Remove back panel, per Back Panel Removal and Replacement
procedure, page 69.
4. At the cooling fan, remove and retain the nuts securing the air
interlock switch onto its bracket (see Figure 141, Figure 142, and
Figure 143, page 73).
5. Replace the air interlock switch if needed.
Page 72 of 95

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents