Microswitch Removal And Replacement - Thermador Pro Grand PRD304EG Service Manual

Hide thumbs Also See for Pro Grand PRD304EG:
Table of Contents

Advertisement

Service Manual for Thermador Pro Grand Dual Fuel Ranges:
Figure 76: Removing the Valve Screw
Figure 77: Standard Valve Connected to Microswitch
1
Screw connecting microswitch to standard valve
58300000157422_ARA_EN_A
PRD304EG, PRD364EDG, PRD364EDPG, PRD364ELG, PRD366EG, PRD366EPG, PRD484ECG, PRD484EEG, PRD486EDG, PRD486EDPG, PRD486ELG
Gas Leaks
With electrical power off, carefully check for gas leaks at each gas
component that was removed, replaced, or otherwise serviced using a
gas leak detector or bubble test.
4.5.3

Microswitch Removal and Replacement

The microswitches are for the standard (non-XLO) burners only.
Be sure to check QuickFinder for relevant information, documentation,
and the correct part number when replacing this component.
Figure 78: Microswitch
1. Follow all safety precautions and steps in Preparing the Range for
Servicing, page 21.
2. Follow all steps in Accessing Components under the Maintop,
page 21.
3. If a burner support rail obstructs access to the microswitch, then
remove the burner support rail (with jet holder assemblies
attached) by following the steps in Removing the Burner Support
Rail, page 24.
4. Remove knob from valve stem by slowly pulling knob straight out,
away from control panel.
5. Using a 9/16th inch wrench, remove the gas tube by unscrewing
the hex nuts connected to the standard valve and to the jet holder
assembly. Be careful not to bend the gas tube.