Item number Item name
611
TC OUTPUT PHASE IN EE MODE
612
TC OUTPUT MUTING IN SEARCH
MODE
619
VITC
628
DF MODE
629
TC SELECT
632
TC UBIT SELECT
633
VITC UBIT SELECT
634
WATCH AUTO ADJUST
651
UMID SDI OUTPUT
102
7-3 Extended Menu
Menu items in the 600s, relating to the time code, metadata, and UMID
Settings
Select the time code output mode for output from the TC OUT connector
in E-E mode.
mutng (muting): Suppress the output.
thru (through): Output the time code input to the TC IN connector as it
v-in (video input phase): Output the time code with the same phase as
v-out (video output phase): Output the time code with the same phase
Select whether to suppress the output from the TC OUT connector in jog/
shuttle mode.
on: Suppress.
off: Do not suppress.
Specify whether or not to record the VITC generated by the internal time
code generator.
off: Do not record internally generated VITC.
on: Record internally generated VITC.
Note
Even if this item is set to "off," VITC is recorded if the input video signal
contains VITC and the VITC line is set to "thru" with item 723.
In 525(U)/525(J) line modes, when the INT/EXT/RP188 switch is set to
INT and the PRESET/REGEN switch is set to PRESET, select the frame
mode of the internal time code generator and counter.
df (on (df)): Drop-frame mode
ndf (off (ndf)): Non-drop frame mode
Select the type of time data to show in the time data display, and the type
of external time code when the INT/EXT/RP188 switch is set to EXT and
the PRESET/REGEN switch is set to REGEN.
vitc: Display time code as VITC, or select VITC as the external time
tc: Display time code as TC, or select TC as the external time code.
See 4-1-2 "Recording Time Code and User Bit Values" (page 44) for
more information about selecting external time code.
When item 629 is set to "tc," specify whether to synchronize the user bits
of the time code generator to the internal clock.
fix: Do not synchronize user bits.
time: Synchronize user bits to the internal clock.
When item 629 is set to "vitc," specify whether to synchronize the user
bits of the time code generator to the internal clock.
fix: Do not synchronize user bits.
time: Synchronize user bits to the internal clock.
When external time code input contains real-time clock user bits, specify
whether to adjust the internal clock to match the real-time clock.
off: Do not adjust the internal clock to match the real-time clock.
on: Adjust the internal clock to match the real-time clock.
Select whether to output UMID in the VANC of the SDI output.
off: Do not output.
on: Output.
See 7-3-3 "Using UMID Data" (page 109) for more information about
UMID.
is.
the input video signal phase.
as the output video signal phase.
code.