Installation; Before Installation; Overview - Graco PrecisionSwirl Instructions-Parts List Manual

Precision dispense system
Table of Contents

Advertisement

Installation

Installation

Before Installation

Have all system and component documentation
available during installation.
See component manuals for specific data on compo-
nent requirements. Data presented here applies to
the PCF assemblies only.
Be sure all accessories are adequately sized and
pressure-rated to meet system requirements.
Use the PCF control center only with the PCF fluid
plate assembly.

Overview

The basic steps to install a PCF system are shown
below. See the separate component manuals for
detailed information.
To avoid injury and damage to equipment, use at
least two people to lift, move, or disconnect the sys-
tem. The system is too heavy for one person to lift or
move.
Installation Steps
1. Mount control center, page 25.
2. For systems with multiple swirl dispensers, mount
expansion Swirl enclosures, page 25.
3. Connect and ground control center and expansion
Swirl enclosures, page 26.
4. Mount each fluid plate assembly, page 27.
5. If using a Coriolis flow meter system, mount the flow
meter, page 149.
6. Ground each fluid plate assembly, page 31.
7. Check ground continuity.
8. Connect fluid lines between each fluid plate and
applicator. Connect fluid supply line and air supply
to module. See page 31.
9. Plumb air filter assembly near air supply drop site
that will be used for fluid plate assembly.
24
10. For systems with swirl dispensers, install each swirl
dispenser onto outlet of a dispense valve.
11. Connect other fluid and air lines to additional system
components as instructed in their manuals.
12. Install fluid plate, swirl, and gateway cable assem-
blies, page 32.
13. Install Gateway interface, page 34.
3A2098S

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcf

Table of Contents