Control Center Assembly
Prepare Control Center for Repair
1. Power off the display.
2. Disconnect main power to the control center
assembly.
3. Remove the control center assembly front cover
(20).
Replace Gateway Module
1. Prepare Control Center for Repair, page 91.
2. Remove the automation communications cable
(AE).
3. Remove the two screws holding the Gateway
module (5) to the base (3), and remove the module.
F
. 63
IG
4. Attach a new Gateway module to the base using
two screws.
5. Reconnect the automation interface cable.
6. Upgrade software, page 81, then upgrade fieldbus
map, page 82.
3A2098S
Replace Gateway Module Base
1. Prepare Control Center for Repair, page 91.
2. Remove the Gateway module (5); follow Replace
Gateway Module. (Leave automation
communications cable (AE) attached to Gateway
module.)
3. Disconnect the CAN cable (19) and power supply
cable (6) from the base (3).
4. Remove the four screws (16) and grounding
screw (12) from the base and replace it with a new
base.
5
F
. 64
IG
3
5. Secure the new base to rear cover (1) using the five
screws.
6. Reattach Gateway module; follow Replace Gate-
way Module.
5
6
3
12
4
Repair
1
19
16
91