Configure Flow Meter Settings

The accuracy of the PCF volume reporting depends on
precise adjustment of the K-factor(s). The fluid plate
uses the K-factor(s) to calculate the volume dispensed.
If the set value is not correct, the system still delivers
repeatable flow rates; however, the reported value may
not be correct. See Verify Flow Meter Calibration,
page 46, for additional K-factor information.
Table 5: Flow Meter K-Factors
Part
Description
246652
High Resolution Helical
Gear Meter
246340
Heated Helical Gear
Meter
16E993
Ultra High Flow Meter
25D026
Coriolis Flow Meter
Set Flow Meter K-Factor
NOTE: In systems without a flow meter, the flow meter
settings will be grayed out.
1. With the system in setup mode, navigate to the Fluid
Plate x, screen 4 (Pressure Loop and Flowmeter
Settings).
2. Press
to access the fields to make changes.
F
. 26
IG
3A2098S
3. Press
and select the meter type used by the system.
Select Volume for volumetric flow meters or Mass
for mass flow meters. Press
selection.
4. Press
K-factor value. See Table 5: Flow Meter K-Factors
for values. Press
K-Factor
5. Press
7000
NOTE: If necessary, verify flow meter calibration. See
3500
Verify Flow Meter Calibration, page 46, for
instructions.
33000
1176
Configure Pressure Loop
Settings
The PCF system uses variables (Kp, Ki, and Kd) in the
software calculations to accurately and precisely control
the fluid pressure.
NOTE: It is recommended that these values are not
changed from the factory defaults of 32.00 for Kp,
128.00 for Ki, and 0.00 for Kd. However, if the values
need to be adjusted, see Manually Adjust Control
Loop Parameters on page 47.
to open the Meter Type drop-down list,
to enter the
to move to the K-Factor field. Key in the
to enter the value.
to exit edit mode.