Technical Data

Technical Data
*Minimum Flow Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 cc/minute with ultra-high resolution (ambient) helical flow meter
*Maximum Flow Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . 4,000 cc/minute with ultra-high resolution (ambient) helical flow
Maximum Fluid Working Pressure
feed pressure to fluid plate (cartridge regulator) . . . .
feed pressure to fluid plate (mastic regulator) . . . . . .
at regulator outlet. . . . . . . . . . . . . . . . . . . . . . . . . . . .
at regulator outlet with electric heat components . . .
feed pressure to fluid plate (Coriolis flow meter / car-
tridge regulator) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Minimum Fluid Working Pressure (at regulator outlet). . . 100 psi (0.7 MPa, 7.0 bar)
Air Supply Pressure Range . . . . . . . . . . . . . . . . . . . . . . . 60-120 psi (0.4 - 0.8 MPa, 4.1- 8.3 bar) - 10 Micron filtration
Fluid Filtration Required . . . . . . . . . . . . . . . . . . . . . . . . . . 30 mesh (500 micron) minimum
*Viscosity Range of Fluids . . . . . . . . . . . . . . . . . . . . . . . . 10,000 to 1,000,000 cps with helical flow meter
*Minimum Dispensed Shot Size. . . . . . . . . . . . . . . . . . . . <1 cc with ultra-high resolution (ambient) helical flow meter
Wetted Parts (meters and fluid plates). . . . . . . . . . . . . . . 303, 304, 321, 17- 4 stainless steel; tungsten carbide, PTFE,
Power Requirements
100-240 Vac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24 Vdc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Supply Voltage Range . . . . . . . . . . . . . . . . . . . . . 100-240 Vac, 50-60 Hz, single phase
Operating Temperature Range
control center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
heated fluid plate . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ambient fluid plate . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Humidity Range. . . . . . . . . . . . . . . . . . . . . . . . 0 - 90% non-condensing
* Flow rates and viscosities are general estimates. Flow rates drop as viscosity increases. Fluids are expected to
shear under pressure. New applications or fluids should always be tested to determine proper line sizes and
equipment selections. See your Graco authorized distributor for other capabilities.

Swirl Dispenser Technical Data

Refer to manual 309403.
148
25 cc/minute with high-resolution (ambient) helical flow meter
50 cc/minute with heated helical flow meter
661 cc/minute with Coriolis flow meter
meter
7,500 cc/minute with high-resolution (ambient) helical flow meter
22,500 cc/minute with heated helical flow meter
65,535 cc/minute with Coriolis flow meter
6000 psi (41 MPa, 414 bar)
5000 psi (35 MPa, 345 bar)
4500 psi (31 MPa, 310 bar)
3500 psi (24 MPa, 241 bar)
5000 psi (35 MPa, 310 bar)
required
3 cc with high-resolution (ambient) helical flow meter
6 cc with heated helical flow meter
steel, fluoroelastomer
full load-1.4A, fuse rating-2.5A
full load-4A, fuse rating-4A
40°F (4°C) - 120°F (49°C)
40°F (4°C) - 400°F (204°C)
40°F (4°C) - 120°F (49°C)