System Setup

Overview

The PCF system compensates for temperature, flow, or
pressure fluctuations. However, if there is a hardware
change on the supply system or the dispense material is
changed, the PCF system must be set up again.
After material is loaded into the supply system, set up
the PCF system using the Setup screens. The following
procedure outlines the major system setup steps. The
following subsections provide instructions to complete
each setup step. Once these steps are complete the
module is ready for operation.
NOTE: See the Advanced Display Module (ADM)
section, page 20, and Appendix A - Advanced Display
Module (ADM), page 104, for detailed operating
instructions for the display keypad and each screen.
NOTE: If configuring an Integrated PCF (without ADM),
at least one ADM must be purchased to allow for setup
and troubleshooting.
1. Configure System, page 36.
2. Configure Control Settings, page 37.
3. Configure Mode Settings, page 38.
4. Configure Delay Settings, page 38.
5. Configure Flow Meter Settings, page 39.
6. Configure Pressure Loop Settings, page 39.
7. Adjust Pressure Sensors, page 40.
8. Configure Errors, page 40.
9. Setup Maintenance Schedule/Parameters, page 41.
10. For systems with swirl dispensers only:
a. Configure Swirl to valve association and error
type, page 41.
b. Configure Swirl settings, page 42.
11. Configure Gateway Settings, page 42.
12. Setup Styles, page 42.
13. Configure Advanced Settings, page 42.
36

Configure System

Define the number of installed fluid plates (called
"Dispenser" on this screen) and number of installed swirl
dispensers. If a fluid plate is listed as "Uninstalled" the
screens for that fluid plate will not appear in the run or
setup screens.
1. With the system in setup mode, navigate to the
System screen.
2. Press
to access the fields to make changes.
3. Use the arrow keys to navigate to the desired field.
4. Press
to open the drop-down list, and select
the desired setting. Press
selection.
5. Repeat for the other Dispensers and Swirl
Dispensers.
6. Press
to exit edit mode.
F
. 22
IG
to accept the
3A2098S