Event and Error Codes and Troubleshooting

Error codes are stored in the events log and are displayed on the error report screens. Gateway error numbers are
reported over the Gateway interface.
Error codes shown as XYZ_ represent error codes XYZ1, XYZ2, XYZ3, XYZ4, where the last digit represents the
number of the fluid plate to which the error applies. Error codes in the following table are sorted by gateway error
number, then by event code.
NOTE: The following error list is available in the PCF
Integration package at www.graco.com.
System Events and Errors
Event
Gateway
Code
Error No.
Event Name
---
0
No Active Errors
EC0X
---
Setup Values
Changed
EL0X
---
Power Up
EM0X
---
Power Down
Control Center Events and Errors
Event
Gateway
Code
Error No.
Event Name
EVUX
---
USB Disabled
MMUX ---
USB Log 90%
Full
V1G0
---
DGM Unpowered The Discrete Gateway
WSG0
---
Gateway Setup
Error
EAUX
---
Download to
USB in Process
3A2098S
Event
Description
Event Type
System Events and Errors
No errors
---
Setup change notifica-
Record only
tion
Control box power up
Record only
Control box power
Record only
down
Event
Description
Event Type
Control Center Events and Errors
USB download
Advisory
attempted, however,
(self-clearing)
USB activity is dis-
abled.
One or more USB log is
Advisory
90% full.
Advisory
Module does not have
logic power supplied to
it.
System settings are
Advisory
incompatible with Dis-
crete Gateway Module.
Information is currently
Advisory
being downloaded to
(self-clearing)
USB
Cause
---
No action necessary
A setup value was
No action necessary if
changed on the dis-
changes were desired
play
---
No action necessary
---
---
Cause
Transfers are dis-
Clears when drive is
abled in Advanced
removed.
Setup screen 2.
Data in the jobs or
Download the data or
events log has not
disable USB errors.
been downloaded
recently and logs are
nearly full.
24 Vdc has not been
Connect power accord-
connected to the
ing to Appendix B -
power pins.
Discrete Gateway
Module (DGM) Con-
nection Details on
page 121.
Fluid plate 1 is not
Install fluid plate 1,
installed. Or Fluid
uninstall fluid plates 3
plate 3 or fluid plate 4
and 4.
is installed.
Swirl 1 is not installed.
Install Swirl 1, uninstall
Or Swirl 3 or Swirl 4 is
swirls 3 and 4.
installed.
---
No action necessary
Errors
Solution
Solution
71